Page 4-D-27 HD 604 S1:1994/A1:1997 _____ Part 4 Section D
CD co
TABLE V
(continued)
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
Number and |
Class of |
Insulation |
Thickness of |
Minimal nominal thickness of the |
Thickness of |
Nominal |
Nominal |
Maximum |
Number and |
||
nominal cross |
conductor |
thickness |
inner sheath |
wires of the armour/PE-conductors |
oversheath |
mean |
copper |
electrical |
nominal cross- |
||
sectional area |
HD 383 |
Specified |
Specified |
|
|
|
Specified |
overall |
equivalent |
resistance of |
sectional area |
of conductors |
|
value |
value |
VO-YMvK |
VG-YMvK |
value |
diameter |
cross-sectional |
the armour/PE |
of conductors |
|
|
|
|
|
as mb |
as mb |
|
|
area of the |
conductor at |
|
|
|
|
|
|
circular wires |
circular wires |
flat wires |
|
|
armour/PE conductor |
20°C |
|
mm2 |
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm’ |
ohm/km |
mm2 |
4 x 1.Б |
1 |
0.7 |
0.8 |
0.3 |
1.0 |
|
1.8 |
1Б |
1.5 |
12.1 |
4 x 1.5 |
4 x 2.5 |
1 |
0.7 |
0.8 |
0.3 |
1.0 |
- |
1.8 |
16 |
2.5 |
7.41 |
4 x 2.5 |
4x 4 |
1 |
0.7 |
0.8 |
0.3 |
1.0 |
* |
1.8 |
17 |
4 |
4.61 |
4x4 |
4 x 6 |
1 |
0.7 |
0.8 |
0.3 |
1.0 |
|
1.8 |
19 |
6 |
3.08 |
4 x 6 |
4x10 |
1 |
0.7 |
0.8 |
0.3 |
1.0 |
|
1.8 |
21 |
10 |
1.83 |
4x 10 |
4x 10 |
2 |
0.7 |
0.8 |
0.3 |
1.0 |
|
1.8 |
22 |
10 |
1.83 |
4x 10 |
4x 16 |
2 |
0.7 |
0.8 |
0.3 |
1.0 |
* |
1.8 |
25 |
16 |
1.15 |
4x 16 |
4x 25 |
2 |
0.9 |
0.9 |
0.3 |
1.0 |
0.8 |
1.8 |
30 |
. 16 |
1.15 |
4x 25 |
4x 35 |
2 |
0.9 |
0.9 |
0.3 |
• |
0.8 |
1.8 |
33 |
16 |
1.15 |
4x 35 |
4 x 50 |
2 |
1.0 |
1.0 |
|
|
0.8 |
1.9 |
37 |
25 |
0.727 |
4x 50 |
4 x 70 |
2 |
1.1 |
1.0 |
|
|
1.4 |
2.1 |
42 |
35 |
0.524 |
4 x 70 |
4 x 95 |
2 |
1.1 |
1.1 |
|
|
1.4 |
2.2 |
50 |
50 |
0.387 |
4 x 95 |
4 x 120 |
2 |
1.2 |
1.2 |
|
|
1.4 |
2.4 |
55 |
60 |
0.306 |
4 x 120 |
4 x 150 |
2 |
1.4 |
1.3 |
- |
|
1.4 |
2.5 |
60 |
75 |
0.248 |
4 x 150 |
4x 18Б |
2 |
1.6 |
1.4 |
|
• |
1.4 |
2.7 |
66 |
95 |
0.193 |
4 x 185 |
4 x 240 |
2 |
1.7 |
1.Б |
|
- |
1.4 |
2.9 |
74 |
120 |
0.153 |
4 x 240 |
4x 300 |
2 |
1.8 |
1.6 |
• |
|
1.4 |
3.1 |
81 |
150 |
0.124 |
4 x 300 |
TABLE V
(concluded)
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
Number and |
Class of |
Insulation |
Thickness of |
Minimal nominal thickness of the |
Thickness of |
Nominal |
Nominal |
Maximum |
Number and |
||
nominal cross |
conductor |
thickness |
inner sheath |
wires of the armour/PE-conductors |
oversheath |
mean |
copper |
electrical |
nominal cross- |
||
sectional area |
HD 383 |
Specified |
Specified |
|
|
|
Specified |
overall |
equivalent |
resistance of |
sectional area |
of conductors |
|
value |
value |
VO-YMvK |
VG-YMvK |
value |
diameter |
cross-sectional |
the armour/PE |
of conductors |
|
|
|
|
|
as mb |
as mb |
|
|
area of the |
conductor at |
|
|
|
|
|
|
|
|
|
|
|
armour/PE |
20°C |
|
|
|
|
|
circular wires |
circular |
flat |
|
|
conductor |
|
|
|
|
|
|
|
wires |
wires |
|
|
|
|
|
mm1 |
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm2 |
ohm/km |
mm’ |
5x 1.6 |
1 |
0.7 |
0.8 |
0.3 |
1.0 |
- |
1.8 |
16 |
1.5 |
12.1 |
5x 1.5 |
5x 2.5 |
1 |
0.7 |
0.8 |
0.3 |
1.0 |
- |
1.8 |
17 |
2.5 |
7.41 |
5x 2.5 |
5x4 |
1 |
0.7 |
0.8 |
0.3 |
1.0 |
|
1.8 |
19 |
4 |
4.51 |
5x 4 |
5x6 |
1 |
0.7 |
0.8 |
. 0.3 |
1.0 |
- |
1.8 |
20 |
6 |
3.08 |
5x6 |
5x10 |
1 |
0.7 |
0.8 |
0.3 |
1.0 |
• |
1.8 |
22 |
10 |
1.83 |
5x10 |
5x10 |
2 |
0.7 |
0.8 |
0.3 |
1.0 |
- |
1.8 |
24 |
10 |
1.83 |
5x10 |
5x16 |
2 |
0.7 |
0.8 |
0.3 |
1.0 |
- |
1.8 |
27 |
16 |
1.15 |
5x16 |
5 x 25 |
2 |
0.9 |
0.9 |
0.3 |
1.0 |
0.8 |
1.8 |
32 |
16 |
1.15 |
5 x 25 |
5 x 35 |
2 |
0.9 |
0.9 |
0.4 |
|
0.8 |
1.9 |
37 |
16 |
1.15 |
5 x 35 |
5 x 50 |
2 |
1.0 |
1.0 |
- |
- |
0.8 |
2.0 |
41 |
25 |
0.727 |
5 x 50 |
5 x 70 |
2 |
1.1 |
1.1 |
- |
- |
0.8 |
2.2 |
47 |
35 |
0.524 |
5 x 70 |
5 x 95 |
2 |
1.1 |
1.2 |
|
• ■ |
1.4 |
2.4 |
55 |
50 |
0.387 |
5x95 |