1. All tests to be considered as type tests.

  2. Clause numbers refer to this section unless stated otherwise.

  3. No separate cold bend test on inner sheath, but compliance to be checked after cold bend test on complete cable.

The oil, ozone and water absorption test shall not be carried out on the innersheath.TABLE IV

GENERAL DATA FOR TYPE YMz.Kmbzh WITH STRANDED-SHAPED CONDUCTORS

1

2

3

4

5

Number and nominal cross­sectional area of conductors mm2

Class of conductor HD 383 (’)

Insulation thickness Specified value mm

Thickness of sheath Specified value mm

Nominal mean overall diameter mm

3

X

35

2

0.9

1.8

22

3

X

50

2

1.0

1.8

24

3

X

70

2

1.1

1.9

28

3

X

95

2

1.1

2.0

32

3

X

120

2

1.2

2.1

34

3

X

150

2

1.4

2.3

39

3

X

185

2

1.6

2.4

43

3

X

240

2

1.7

2.6

48

4

X

35

2

0.9

1.8

25

4

X

50

2

1.0

1.9

27

4

X

70

2

1.1

2.0

32

4

X

95

2

1.1

2.1

36

4

X

120

2

1.2

2.3

39

4

X

150

2

1.4

2.4

44

4

X

185

2

1.6

2.6

49

4

X

240

2

1.7

2.8

55



For special purposes Class 1 aluminium conductors may be applied.TABLE V


GENERAL DATA FOR TYPES Z.O-YMz.Kasmbzh AND Z.G-YMz.Kasmbzh WITH CIRCULAR CONDUCTORS


1

2

3

4

5

6

7

8

9

10

11

12

Number and

Class of

Insulation

Thickness of

Minimal nominal thickness of the

Thickness of

Nominal

Nominal

Maximum

Number and

nominal cross sectional area

conductor HD 383

thickness Specified

inner sheath Specified

wires of the arm

our/PE-conductors

oversheath Specified

mean overall

copper equivalent

electrical resistance of

nominal cross­sectional area

of conductors mm*"


value mm

value mm

Z,0-YMz,K asmbzh

circular wires

mm

Z.G-Y asm

circular wires mm

Mz,K bzh

flat wires

mm

value mm

diameter mm

cross-sectional area of the armour/PE conductor mm2

the armour/PE conductor at 20°C ohm/km

of conductors mm’

1 x 1.6

1

0.7

0.8

0.3

1.0

-

1.8

11

1.6

12.1

1 x 1.6

1 X 2.5

1

0.7

0.8

0.3

1.0


1.8

11

2.6

7.41

1 x 2.5

1 x 4

1

0.7

0.8

0.3

1.0

-

1.8

12

4

4.61

1 x 4

1 x 6

1

0.7

0.8

0.3

1.0

-

1.8

12

6

3.08

1 x 6

1 x 10

1

0.7

0.8

0.3

1.0


1.8

13

10

1.83

1 x 10

1 x 10

2

0.7

0.8

0.3

1.0

-

1.8

14

10

1.83

1 x 10

1 x 16

2

0.7

0.8

0.3

1.0

-

1.8

16

16

1.15

1 x 16

1 x 25

2

0.9

0.8

0.3

1.0


1.8

16

16

1.15

1 x 25

1 x 35

2

0.9

0.8

0.3

1.0

-

1.8

18

16

1.15

1 x 35

1 x 60

2

1.0

0.8

1.0

-

1.8

19

25

0.727

1 x 50

1 x 70

2

1.1

0.8

-

1.0

1.4

1.8

22

35

0.524

1 x 70

1 x 95

2

1.1

0.8

-

1.0

1.4

1.8

24

60

0.387

1 x 95

1 x 120

2

1.2

0.8

*

(21

(2)

1.8

27

60

0.306

1 x 120

1 x 150

2

1.4

0.8

-

(2)

(2)

1.8

29

75

0.248

1 x 160

1 x 185

2

1.6

0.9


(2)

(2)

1.8

32

95

0.193

1 x 185

1 x 240

2

1.7

0.9

-

(2)

(21

1.9

35

120

0.153

1 x 240

1 x 300

2

1.8

1.0

*

(2)

(21

1.9

38

150

0.124

1 x 300

1 x 400

2

2.0

1.0

-

(2)

(2)

2.1

42

200

0.0940

1 x 400

1 x 600

2

2.2

1.1

-

(2)

(2)

2.2

47

260

0.0732

1 x 500

1 x 630

2

2.4

1.1

-

(2)

(2)

2.3

61

315

0.0566

1 x 630

1 x 800

2

2.6

1.2

»

<2>

(2)

2.4

66

400

0.0470

1 x 800

1 x 1000

2

2.8

1.3

(2)

(2)

2.6

62

500

0.0366

1 x 1000

111 Single core cables with an armour/PE conductor made up partly of steel wires are for direct current only.

121 The shape and dimensions of armour wires for conductor sizes of 120mm2 and above are left to the choice of the manufacturer

Page 5-C-26

HD 604 S1:1994/A1:1997

Part 5 Section C






























TABLE VI


GENERAL DATA FOR TYPE Z.G-YMz,Kasmbzh
WITH STRANDED SHAPED CONDUCTOR


і і

I I

I I

I I і

і


1

2

3

4

5

6

7

8

9

10

11

Number and

Class of

Insulation

Thickness

Minimal nominal

Thickness of

Nominal mean

Nominal

Maximum

Number

nominal

conductor

thickness

of inner

thickness of the

oversheath

overall

copper

electrical

and

cross

HD 383

Specified

sheath

wires of the armour/

Specified

diameter

equivalent

resistance of

nominal

sectional


Value

Specified

PE conductor

value


cross-

the armour/

cross-

area of



Value





sectional

PE conductor

sectional

conductor








area of the

at 20eC

area of









armour/ PE


conductors









conductor







flat

conductor










wires

wires






mm’


mm

mm

mm

mm

mm

mm

mm’

ohm/km

mm2

3 x 35

2

0.9

0.8

0.8

1.0

1.8

25

16

1.15

3x 35

3 x 50

2

1.0

0.8

0.8

1.0

1.8

27

25

0.727

3 x 50

3x 70

2

1.1

0.9

0.8

1.0

2.0

31

35

0.524

3 x 70

3 x 95

2

1.1

1.0

0.8

1.0

2.1

35

50

0.387

3 x 95

3 x 120

2

1.2

1.0

0.8

1.0

2.2

38

60

0.306

3 x 120

3 x 150

2

1.4

1.1

0.8

1.0

2.4

42

75

0.248

3 x 150

3 x 185

2

1.6

1.1

0.8

1.0

2.5

46

96

0.193

3 x 185

3 x 240

2

1.7

1.2

1.4

1.6

2.7

52

120

0.153

3 x 240

4x 35

2

0.9

0.8

0.8

1.0

1.8

27

16

1.15

4x 35

4 x 60

2

1.0

0.9

0.8

1.0

1.9

30

25

0.727

4x 50

4 x 70

2

1.1

1.0

0.8

1.0

2.1

35

35

0.524

4x 70

4x 95

2

1.1

1.0

0.8

1.0

2.2

39

50

0.387

4x 95

4 x 120

2

1.2

1.1

0.8

1.0

2.4

43

60

0.306

4x 120

4 x 150

2

1.4

1.1

0.8

1.0

2.5

47

75

0.248

4 x 150

4 x 185

2

1.6

1.2

1.4

1.6

2.7

53

95

0.193

4 x 185

4 x 240

2

1.7

1.3

1.4

1.6

2.9

59

120

0.153

4 x 240