Technical Features

Active IR beams

Microwave

Duabtech 'barriers?

Video Motion Detection

Active Video Detection

Passive IR

PIR + doppler

Rotating Laser

Radar


causes










False alarms causes










Identification (video confirmation)


No

No

Yes

No

No

No

No

No

Dissuasion

Little

Little

Little

Little

Little

Little

Little

Little

Little

Intrusion delayed


No

No

No

No

No

No

No

No

D.4 Fence-mounted sensors

Table D.4 — Fence-mounted equipment

Functional features

Microphonic sensitive cable

Fibre optics

sensitive cable

Vibration sensor

Copper cable

Detection zone features

Range

100 m up to

300 m

Up to 80 km

100 m up to

300 m

100 m up to

300 m

Width: volume or curtain

NA

NA

NA

NA

Height

Depends

Depends

Depends

Depends

Dead zone

No

No

No

No

Detection performance on non-even grounds

Yes (depends on fence)

Yes (depends on fence)


NA

Detection on

ground with no hollow plan

Yes (depends on fence)

Yes (depends on fence)



Disqualification

Yes (sabotage)

Yes (sabotage)

Yes (sabotage)

Yes (sabotage)

Configuration of the width or sensitivity of the detection zone

Yes

Yes

Yes

No

Technology

Optical, radiofrequency, thermal, seismic

Piezoelectric

Fiber Optics + laser







Seismic


Passive

Passive


Passive

Detection features

Vertical detection

Yes (depends on fence)

Yes (depends on fence)


No

Ground-level detection

Yes

Yes

Yes

Yes

Minimum intrusion speed

Depends on fence

Depends on fence



Maximum intrusion speed

Depends on fence

Depends on fence


Easy

Resolution of detection

5 m to 25 m

5 m to 25 m


Not possible

Discrimination capacity

Maximum of non­intruder object

NA

NA



Minimum detected mass without alarm

NA

NA



Intrusion qualification

Intrusion location: video- confirmation

5 m up to 10,0m

No


5 m

Target dimension

?

?


Yes 5 m with certain models (according to



Functional features

Microphonic sensitive cable

Fibre optics

sensitive cable

Vibration sensor

Copper cable






size)

Target height

?

?


No

Immunity to

weather variations

Immunity to sun glare

NA

NA

NA

NA

Maximum range in fog (in % of the Weather

Optical range)

Insensitive

Insensitive

Insensitive

Insensitive

Rain

Insensitive

Insensitive

Insensitive

Insensitive

Snow

Insensitive

Insensitive

Insensitive

Insensitive

Wind

Insensitive

Insensitive

Insensitive

Insensitive

Immunity to

other disturbances

Electro-magnetic

Insensitive

Insensitive

Insensitive

Insensitive

Underground vibrations

Insensitive

Insensitive

Insensitive

Insensitive

Underground fluids

Insensitive

Insensitive

Insensitive

Insensitive

Main causes of false alarms

Storm, strong EMI

Storm



Wiring /

installation

NO/NC output

Yes

Yes



Serial output

Yes

Yes



Native IP

communication

Yes

Yes



connection between active equipment

No

No



Other criteria

Non-detection causes





Causes of false alarms





Identification (video confirmation)

No

No



Dissuasion

No

No



Intrusion delayed







D.5 Active Physical security

Table D.5 — Comparative of perimetric detection technologies

Functional features

Taut wire

Electric fence

Sensitive barbed wire

Active fence

Sensitive net

Sensitive outrigger s

Detection features

zone

Range

20 m up to

50 m

Variable from 20 m to 1 500 m

20 m up to 500 m

20 m up to 50 m

20 m up to

50 m

20 m up to

50 m


Width: volume or curtain

NA

NA

NA

NA

NA

NA



Functional features

Tautwire

Electric fence

Sensitive barbed wire

Active fence

Sensitive net

Sensitive outrigger s


Height

according to need

according to need

according to need

accordin g to need

according to need

according to need

Dead zone

No

No

No

No

No

No

Detection performance on non-even grounds

Yes

Yes

Yes

Yes

Yes

Yes

Detection of

concave areas

Yes

Yes

Yes

Yes

Yes

Yes

Disqualification

NA

NA

NA

NA

NA

NA

Configuration of the width or sensitivity of the detection zone

Yes

Yes

Yes

Yes

Yes

Yes

Technology

Optical, radiofrequency, thermal, seismic

Electric or electro­mechanic or piezo­electric or pressio tube

Electric

Electric

Electric or optic

Electric or optic

Electric

Detection features

Vertical detection

Yes

Yes

Yes

Yes

Yes

Yes

Ground-level detection

Yes

Yes

Yes

Yes

Yes

Yes

Minimum intrusion speed

With or without destruction

With or without destruction

With or without destruction

With or without destructi on

With or without destruction

With or without destructio n

Maximum intrusion speed

With or without destruction

With or without destruction

With or without destruction

With or without destructi on

With or without destruction

With or without destructio n

Resolution of detection

NA

NA

NA

NA

NA

NA

Discrimination capacity

Maximum of

non-intruder object

NA

NA

NA

NA

NA

NA

Minimum detected mass without alarm

20 kg

NA

NA

20 kg

20 kg

20 kg

Intrusion qualification

Intrusion location: video­confirmation

20 m up to

50 m

20 m up to 200 m by zone of detection

20 m up to 500 m by zone of detection

20 m up to 100 m by zone of detection

20 m up to

50 m

20 m up to 50 m

Target dimension

NA

NA

NA

NA

NA

NA

Target height

NA

NA

NA

NA

NA

NA

Immunity to

Immunity to sun

No

Not

Not

Not

No

No



Functional features

Taut wire

Electric fence

Sensitive barbed wire

Active fence

Sensitive net

Sensitive outrigger s

weather variations

glare


sensitive to light

sensitive to light

sensitive to light



Maximum range in fog (in % of the Weather

Optical range)

No

Not sensitive to fog

Not sensitive to fog

Not sensitive to fog

No

No

Rain

No

No

Not sensitive to rain

Not sensitive to rain

No

No

Snow

No

No

No

No

No

No

Wind

No

No

No

No

No

No

Immunity to

other disturbances

Electro-magnetic

Slightly sensitive

Slightly sensitive

Slightly sensitive

Slightly sensitive

Slightly sensitive

Slightly sensitive

Underground vibrations

No

Not sensitive

Not sensitive

Not sensitive

No

No

Underground fluids

No

not sensitive

not sensitive

not sensitive

No

No

Main causes of false alarms







Wiring /

installation

NO/NC output

Yes

Yes

Yes

Yes

Yes

Yes

Serial output

Yes

Yes

Yes

Yes

Yes

Yes

Native IP

communication

Yes

Yes

Yes

Yes

Yes

Yes

Connection between active equipment

No

Yes

Yes

Yes

No

No

Other criteria

Causes of non­detection







Causes of false alarms







Identification (video confirmation)

No

No

No

No

No

No

Dissuasion

Average because obstacle and presence are visible

Very dissuasive thanks to unpleasant effect and visible presence

Very dissuasive because hurtful

Average because obstacle and presence visible

Average because obstacle and presence visible

Average because obstacle and presence visible and trapping effect

Intrusion delayed

Yes

Yes

Yes

Yes

Yes

Yes