related to the choice of deck and pitch for Test 1

FIELD OF APPLICATION

Choice of deck for test 1

Actual intended deck

Standard supporting deck

Deck a

Wood particle boards 16 mm thick with gaps < 0,5 mm

Deck b Wood particle boards 16 mm thick with gaps of 5 mm

Deck c Continuous non combustible board of 10 mm thickness without gaps

Deck d

Trapezoidal profiled steel deck

Deck e

Without any continuous deck

ACTUAL TESTED DECK

X






NON PROFILED CONTINUOUS DECK

Wooden continuous deck (>= 16 mm) with gap not exceeding 0,5 mm


X

X




Wooden continuous deck with gap not exceeding 5 mm



X




Continuous non combustible board of minimum 10 mm thickness without gaps


X

X

X

X


Non combustible board of minimum 10 mm thickness with gaps not exceeding 5 mm



X




|ac) Trapezoidal profiled not perforated steel deck




X


X

(AC]

Roof without a continuous deck







X



Choice of pitch for test 1

FIELD OF APPLICATION

Pitch for test

Single tested pitch other than 15° or 45 °С

15°

45°

Single tested pitch

X



0° < pitch < 20°


X


20° < pitch



X



  1. - Field of direct application of test results

|ac> related to the choice of substrate and pitch for Test 2 <acJ

FIELD OF APPLICATION

Choice of substrate for test 2

Non standard substrate

Standard substrate for test 2

Substrate a: Wood particle boards

Substrate b: expanded polystyrene

Substrate c: fibre reinforced calcium silicate board

Substrate d: mineral wool

(*) All densities > 0,75 x density of substrate tested

Substrate tested (*)

X





Combustible substrate (*)


X

X



Non combustible substrate (*)


X

X

X

X



Choice of pitch for test 2

FIELD OF APPLICATION

Pitch for test

30°

All pitches

X



  1. - Field of direct application of test results
    related to the choice of deck and pitch for Test 3

FIELD OF APPLICATION

Choice of deck for test 3

Alternative supporting deck

Standard supporting deck for test 3

Wood particle boards 16 mm thick with gaps not exceedinq

Wood particle boards 16 mm thick with gaps of 5

Continuous non combustible board of 12 mm

Deck d Trapezoidal steel deck

Deck e Without any continuous deck

ROOF SYSTEM TESTED

X






NOT PROFILED CONTINOUS DECK

Wooden continuous deck (> 12 mm) with gap not exceeding 0,5 mm


X

X




Wooden continuous deck (> 12 mm) with gap not exceeding 5 mm



X




Continuous non combustible board of minimum 10 mm thickness without gaps


X

X

X

X


Non combustible board of minimum 10 mm thickness with gaps not exceeding 5 mm



X




Trapezoidal non­perforated profiled steel deck






X


Roof without a continuous deck







X



Choice of pitch for test 3



FIELD OF APPLICATION

Pitch for test



Actual only single intended pitch

30°

Actual only single intended pitch

X



0°< pitch <10°


X


10° < pitch <70°



X



Ei) Table B.4 — Field of direct application of test results related to the choice of deck, supporting
structure and pitch for test 4

Field of application

Choice of deck and supporting structure for test 4

All roof systems

The classification is valid only for the deck and supporting structure as tested



Choice of pitch for test 4

Field of application

Pitch for test

Single intended pitch

45°

Single intended pitch

X



0° < pitch < 10°


X


10° < pitch <70°



X