Table 4 - Access control systems (continued)


- 51 - CLC/TR50531:2009




No.

Term

Definition

Ref. publication

Year

Ref.

4.52

proximity

mode of operation to offer the user identity to the recognition equipment without requiring contact

EN 50133-7

1999

A 29

4.53

memorised information

information known to the user

EN 50133-1

1996

3.21

4.54

normal condition

the access control system is fully functional and able to process all events according of the

EN 50133-1

1996

3.22



pre-set rules

EN 50131-1

2006

3.1.47




CLC/TS 50131-3

2003

3.1.36




CLC/TS 50131-7

2003

3.1.27




EN 50134-1

2002

3.10




EN 50134-2

1999

3.13




EN 50134-3

2001

3.11

4.55

person trap

a means of limiting the number of user(s) passing an access point at the same time

EN 50133-7

1999

A.27

4.56

personal code

individual memorised information

EN 50133-7

1999

A.25

4.57

Personal Identification

synonymous with personal code (A.25 of EN 50133-7)

EN 50133-7

1999

A.26


Number - called "PIN"




4.58

power supply

that part of an access control system which provides power for the operation of the system or

EN 50133-1

1996

3.23



any part of thereof

EN 50131-1

2006

3.1.54




CLC/TS 50131-7

2003

3.1.30




CLC/TS 50131-3

2003

3.1.41




EN 50131-6

2008

3.1.1




EN 50486

2008

2.1.7

4.59

presence check

control of the number (max., min.) of persons within a security controlled area

EN 50133-7

1999

3.9





Table 4 - Access control systems (continued)


CLC/TR 50531:2009 - 52 -




No.

Term

Definition

Ref. publication

Year

Ref.

4.60

processing

the comparing of information with pre-set rules to make decision concerning the granting or denying of access to users and/or the comparing of events with pre-set rules to produce appropriate actions

EN 50133-1

1996

3.24

4.61

programmability

ability to receive and store pre-set rules

EN 50133-1

1996

3.25

4.62

protected area

synonymous with security controlled area (3.27 of EN 50133-1)

EN 50133-7

1999

A.28

4.63

release

the signal to the APAS that access has been granted

EN 50133-1

1996

3.26

4.64

security controlled area

area surrounded by physical barner, including one or more access points

EN 50133-1

1996

3.27

4.65

security zone

synonymous with security controlled area (3.27 of EN 50133-1)

EN 50133-7

1999

A.30

4.66

singularisation

limitation to one user passing an access point at the same time

EN 50133-7

1999

3.10

4.67

tamper protection

methods used to protect an access control system or part thereof against deliberate interference

EN 50133-1

1996

3.28




EN 50131-1

2006

3.1.74




CLC/TS 50131-3

2003

3.1.55




CLC/TS 50131-7

2003

3.1.42

4.68

time grid

one or more time zones allocated to an access level

EN 50133-1

1996

3.29

4.69

time slot

interval of time between two given moments indicating the beginning and end of a valid period within time zone

EN 50133-1

1996

3.31

4.70

time zone

one or more time slots combined with calendar information

EN 50133-1

1996

3.30

4.71

timed anti-passback

operating mode which inhibits the access granting process at an access point or to a security controlled area for a preset period for a particular user once that user has been granted access

EN 50133-7

1999

3.1.2

4.72

token

recognition data provided by access cards, keys, tags, etc

EN 50133-1

1996

3.32

4.73

transaction

an event which correspond to the release of an access point following recognition of a user identity

EN 50133-1

1996

3.33

Table 4 - Access control systems (continued)


-53- CLC/TR 50531:2009


No.

Term

Definition

Ref. publication

Year

Ref.

4.74

two users access condition

procedure which ensures that access is granted provided two users have demonstrated their right of access within preset period

EN 50133-7

1999

3.12

4.75

user

a person requesting passage through an access point

EN 50133-1

1996

3.34




EN 50131-1

2006

3.1.80




CLC/TS 50131-3

2003

3.1.59




CLC/TS 50131-7

2003

3.1.45




EN 50134-2

1999

3.11




EN 50134-3

2001

3.23




CLC/TS 50134-7

2003

3.11

4.76

user identity

information which is transferred directly or via a token by the user to the recognition equipment

EN 50133-1

1996

3.35

a Renumbered reference per Eh

50136-1-1:1998/A2:2008.




Table 4 - Access control systems (continued)


CLC/TR 50531:2009 - 54 -
















No.

Term

Definition

Ref. publication

Year

Ref.

5.01

activity monitoring

an alarm function that operates automatically when a routine activity of the user, being monitored

EN 50134-2

1999

3.7


trigger device

by a trigger device, is modified or omitted within a specified period

EN 50134-3

2001

3.8

5.02

alarm condition

a condition following the pre-alarm condition

EN 50134-1

2002

3.9




EN 50134-2

1999

3.12




EN 50134-3

2001

3.13




EN 50134-5

2004

3.1.9




EN 50131-1

2006

3.1.8




CLC/TS 50131-3

2003

3.1.5




CLC/TS 50131-7

2003

3.1.5




EN 50136-1-1

1998

4.1.1 a

5.03

Alarm Receiving Centre

system part which provides facilities for communication with a number of controllers and providing

EN 50134-1

2002

3.2


(ARC)

the alarm receiving and information processing system as an interface to the alarm recipient

EN 50134-3

2001

3.2




EN 50134-5

2004

3.1.2




CLC/TS 50134-7

2003

3.2




EN 50131-1

2006

3.1.6




CLC/TS 50131-3

2003

3.1.8




CLC/TS 50131-7

2003

3.1.3




EN 50136-1-1

1998

4.1.2а




CLC/TS 50398

2002

3.4

Table 5 - Social alarm systems


-55- CLC/TR 50531:2009



No.

Term

Definition

Ref. publication

Year

Ref.

5.04

alarm receiving service

a staffed service for the receipt and processing of alarm calls from an alarm system

CLC/TS 50134-7

2003

3.18

5.05

alarm receiving station

a personal receiver or an ARC terminal at which calls are received and processed by an alarm recipient

CLC/TS 50134-7

2003

3.17

5.06

alarm recipient

person who receives and acts upon an alarm signal

EN 50134-1

2002

3.14




EN 50134-3

2001

3.22




EN 50134-5

2004

3.15




CLC/TS 50134-7

2003

3.9

5.07

alarm signal

signal transmitted by the controller to an alarm receiving centre to indicate an alarm condition or a

CLC/TS 50134-7

2003

3.22



fault condition

CLC/TS 50131-3

2003

3.1.9

5.08

alarm transmission

transmission system that provides communication between the controller and the alarm receiving

EN 50134-1

2002

3.7


system

centre or an alarm recipient

EN 50134-3

2001

3.10




CLC/TS 50134-7

2003

3.7




EN 50136-1-1

1998

4.1.7 а




EN 50131-1

2006

3.1.11




CLC/TS 50131-3

2003

3.1.11




CLC/TS 50131-7

2003

3.1.7




CLC/TS 50398

2002

3.9




CLC/TR 50456

2008

2.1.3

Table 5 - Social alarm systems (continued)


CLC/TR 50531:2009 - 56 -
























T

CLC/TR 50531:2009

able 5 - Social alarm systems (continued)

No.

Term

Definition

Ref. publication

Year

Ref.

5.09

alarm triggering signal

signal transmitted by a trigger device to indicate an alarm

EN 50134-1

2002

3.13




EN 50134-3

2001

3.20




EN 50134-5

2004

3.1.14

5.10

availability

the percentage of time during which the system is known to be available to transmit an alarm condition or an alarm triggering event without corruption and within the specified transmission time

CLC/TS 50134-7

2003

3.20

5.11

controller

interface between one or more local units and the alarm transmission system or alarm recipient

EN 50134-1

2002

3.3




EN 50134-2

1999

3.2




EN 50134-3

2001

3.4




EN 50134-5

2004

3.1.3




CLC/TS 50134-7

2003

3.3




EN 50133-7

1999

A.11

5.12

disconnection condition

temporary and deliberate disconnection of a local unit to prevent alarm or fault transmission to the controller or the alarm receiving centre

EN 50134-3

2001

3.15

5.13

disconnection indication

indication of the disconnection condition

EN 50134-3

2001

3.19