No. |
Term |
Definition |
Ref. publication |
Year |
Ref. |
5.14 |
fault condition |
condition following detection of a fault by the local unit and controller that prevents the functioning of the system |
EN 50134-1 |
2002 |
3.11 |
|
|
|
EN 50134-3 |
2001 |
3.14 |
|
|
|
EN 50134-5 |
2004 |
3.1.10 |
|
|
|
CLC/TS 50134-7 |
2003 |
3.8 |
|
|
|
EN 50131-1 |
2006 |
3.1.26 |
|
|
|
CLC/TS 50131-3 |
2003 |
3.1.21 |
|
|
|
CLC/TS 50131-7 |
2003 |
3.1.17 |
|
|
|
EN 50133-1 |
1996 |
3.20 |
|
|
|
CLC/TS 50136-4 |
2004 |
3.13 |
|
|
|
CLC/TS 50398 |
2002 |
3,21 |
5.15 |
fault indication |
indication of a fault condition |
EN 50134-1 |
2002 |
3.12 |
|
|
|
EN 50134-3 |
2001 |
3.17 |
|
|
|
EN 50134-5 |
2004 |
3.1.12 |
5.16 |
fault reporting time |
maximum interval from the time a fault occurs in the interconnection until the transmission of a |
CLC/TS 50134-7 |
2003 |
3.10 |
|
|
fault signal is initiated by the controller |
EN 50134-5 |
2004 |
3.1.16 |
5.17 |
fault warning signal |
any signal transmitted by a trigger device to indicate battery low or faulty condition of the trigger |
EN 50134-2 |
1999 |
3.14 |
5.18 |
fire alarm system |
a component of a fire detection system which contains at least one sensor which constantly, or at |
EN 50134-2 |
1999 |
3.8 |
|
trigger |
frequent intervals, monitors at least one suitable, physical and/or chemical phenomenon associated with gas that provides an alarm triggering signal to be received and processed by the local unit and controller |
|
|
|
5.19 |
fixed trigger device |
a trigger device in a fixed position in relation to the local unit or building |
EN 50134-2 |
1999 |
3.5 |
|
|
|
EN 50134-3 |
2001 |
3.6 |
Table 5 - Social alarm systems (continued)
CLC/TR 50531:2009 - 58 -
No. |
Term |
Definition |
Ref. publication |
Year |
Ref. |
5.20 |
gas alarm trigger |
a component of a gas detection system which contains at least one sensor which constantly, or at frequent intervals, monitors at least one suitable physical and/or chemical phenomenon associated with gas that provides an alarm triggering signal to be received and processed by local unit and controller |
EN 50134-2 |
1999 |
3.9 |
5.21 |
helper |
person who attends and gives assistance to a user as a result of an alarm call |
CLC/TS 50134-7 |
2003 |
3 14 |
5.22 |
interconnections |
transmission system that provides the communication between trigger devices and local unit and |
CLC/TS 50134-7 |
2003 |
3,6 |
|
|
controller |
EN 50134-2 |
1999 |
3.10 |
|
|
|
EN 50134-3 |
2001 |
3.9 |
|
|
|
EN 50131-1 |
2006 |
3.1.33 |
|
|
|
CLC/TS 50131-3 |
2003 |
3.1.27 |
|
|
|
CLC/TS 50131-7 |
2003 |
3.1.23 |
5.23 |
life-critical call |
any alarm call received at an alarm receiving station for which, from the information available to the alarm recipient prior to acceptance of that call, it is not obvious that the call is in respect of an equipment test or fault |
CLC/TS 50134-7 |
2003 |
3.16 |
5.24 |
local unit |
interface between the user and the controller which enables 2-way speech |
EN 50134-1 |
2002 |
3.4 |
|
|
|
EN 50134-2 |
1999 |
3.3 |
|
|
|
EN 50134-3 |
2001 |
3.3 |
|
|
|
EN 50134-5 |
2004 |
3.1.4 |
|
|
|
CLC/TS 50134-7 |
2003 |
3.4 |
Table 5 - Social alarm systems (continued)
-59- CLC/TR 50531:2009
No. |
Term |
Definition |
Ref. publication |
Year |
Ref. |
5.25 |
normal condition |
condition during which the system is fully operational and is not in any other condition |
EN 50134-1 |
2002 |
3.10 |
|
|
|
EN 50134-2 |
1999 |
3.13 |
|
|
|
EN 50134-3 |
2001 |
3.11 |
|
|
|
EN 50131-1 |
2006 |
3.1.47 |
|
|
|
CLC/TS 50131-3 |
2003 |
3.1.36 |
|
|
|
CLC/TS 50131-7 |
2003 |
3.1.27 |
|
|
|
EN 50133-1 |
1996 |
3.22 |
5.26 |
personal receiver |
system part which provides 2-way speech communication and facilities for identifying and acknowledging the alarm |
EN 50134-1 CLC/TS 50134-7 |
2002 2003 |
3.6 3.12 |
5.27 |
portable trigger device |
a trigger device carried by the user and providing wire-free communication |
EN 50134-2 |
1999 |
3.6 |
|
|
|
EN 50134-3 |
2001 |
3.7 |
|
|
|
CLC/TS 50134-7 |
2003 |
3.13 |
5.28 |
pre-alarm condition |
condition following the reception of an alarm triggering signal |
EN 50134-1 |
2002 |
3.8 |
|
|
|
EN 50134-3 |
2001 |
3.12 |
|
|
|
EN 50134-5 |
2004 |
3.1.8 |
5.29 |
pre-alarm warning indication |
indication at the local unit that the local unit is in the pre-alarm condition |
EN 50134-3 EN 50134-5 |
2001 2004 |
3.18 3.1.11 |
5.30 |
reassurance indication |
indication provided locally in alarm condition in order to verify to the user that the local unit has received the alarm triggering signal |
EN 50134-3 EN 50134-5 |
2001 2004 |
3.16 3.1.13 |
5.31 |
reference impedance ZR |
a complex impedance made up of 270 Ohm in series with a parallel combination of 750 Ohm and 150 nF |
EN 50134-5 |
2004 |
3.1.17 |
Table 5 - Social alarm systems (continued)
CLC/TR 50531:2009 - 60 -
No. |
Term |
Definition |
Ref. publication |
Year |
Ref. |
5.32 |
reset |
return of the alarm system to the normal condition |
EN 50134-3 |
2001 |
3.21 |
5.33 |
service provider |
an individual or organisation having an agreement with a user to provide a social alarm service |
CLC/TS 50134-7 |
2003 |
3.15 |
5.34 |
social alarm service |
a service provided to an individual which uses or is mediated through a social alarm system |
CLC/TS 50134-7 |
2003 |
3.21 |
5.35 |
social alarm system |
system providing 24 hour facilities for alarm triggering, identification, signal transmission, alarm reception, 2-way speech communication, reassurance and assistance, for use by persons who can |
EN 50134-1 |
2002 |
3.1 |
|
|
be considered to be living at home at risk |
EN 50134-2 |
1999 |
3.1 |
|
|
|
EN 50134-3 |
2001 |
3.1 |
|
|
|
EN 50134-5 |
2004 |
3.1.1 |
|
|
|
CLC/TS 50134-7 |
2003 |
3.1 |
|
|
|
EN 50130-5 |
1998 |
3.1.3 |
|
|
|
EN 50130-4 |
1995 |
3.1.6 |
|
|
|
CLC/TR 50456 |
2008 |
2.1.9 |
5.36 |
transmission time |
the time measured from when the local unit and controller enters the alarm condition until the |
CLC/TS 50134-7 |
2003 |
3.19 |
|
|
alarm condition is reported at the alarm receiving station |
EN 50136-1-1 |
1998 |
4.1.26 а |
5.37 |
trigger device |
system part, operated by a human or automatically, that communicates to the local unit and controller, initiating the alarm triggering signal |
EN 50134-1 |
2002 |
3.5 |
|
|
|
EN 50134-2 |
1999 |
3.4 |
|
|
|
EN 50134-3 |
2001 |
3.5 |
|
|
|
EN 50134-5 |
2004 |
3.1.5 |
|
|
|
CLC/TS 50134-7 |
2003 |
3.5 |
Table 5 - Social alarm systems (continued) -61- CLC/TR 50531:2009 No. |
Term |
Definition |
Ref. publication |
Year |
Ref. |
5.38 |
user |
person benefiting from a service provided via a social alarm system |
EN 50133-1 |
1996 |
3.34 |
|
|
|
EN 50131-1 |
2006 |
3.1.80 |
|
|
|
CLC/TS 50131-3 |
2003 |
3.1.59 |
|
|
|
CLC/TS 50131-7 |
2003 |
3.1.45 |
|
|
|
EN 50134-2 |
1999 |
3.11 |
|
|
|
EN 50134-3 |
2001 |
3.23 |
|
|
|
CLC/TS 50134-7 |
2003 |
3.11 |
a Renumbered reference per EN 50136-1-1:1998/A2:2008. |
Table 5 - Social alarm systems (continued)
CLC/TR 50531:2009 - 62
No. |
Term |
Definition |
Ref. publication |
Year |
Ref. |
6.01 |
alarm condition |
a condition of an alarm system, or part thereof, which results from the response of the system, or |
EN 50136-1-1 |
1998 |
4.1.1 3 |
|
|
part thereof, to the presence of a hazard |
EN 50131-1 |
2006 |
3.1.8 |
|
|
|
CLC/TS 50131-3 |
2003 |
3.1.5 |
|
|
|
CLC/TS 50131-7 |
2003 |
3.1.5 |
|
|
|
EN 50134-1 |
2002 |
3.9 |
|
|
|
EN 50134-2 |
1999 |
3.12 |
|
|
|
EN 50134-3 |
2001 |
3.13 |
|
|
|
CLC/TS 50398 |
2002 |
3.6 |
6.02 |
alarm messages |
messages which contain a warning that a hazard (or a potential hazard) to life or property exists at one or more of the connected alarm systems |
CLC/TS 50136-4 |
2004 |
3.2.1 |
6.03 |
alarm receiving centre |
a continuously manned centre to which information concerning the status of one or more alarm |
EN 50136-1-1 |
1998 |
4.1.2а |
|
(central station) |
system is reported |
EN 50131-1 |
2006 |
3.1.6 |
|
|
|
CLC/TS 50131-3 |
2003 |
3.1.8 |
|
|
|
CLC/TS 50131-7 |
2003 |
3.1.3 |
|
|
|
CLC/TS 50398 |
2002 |
3.4 |
|
|
|
EN 50134-1 |
2002 |
3.2 |
|
|
|
EN 50134-3 |
2001 |
3.2 |
|
|
|
CLC/TS 50134-7 |
2003 |
3.2 |