Fire behaviour


Smoke production


Flaming droplets

A1 to F (as applicable)


s

1,2 or 3 (as applicable)


d

0, 1 or 2 (as applicable)



i.e. A1 to F (as applicable) -s1, 2 or 3 (as applicable), dO, 1 or 2 (as applicable)

The format of the reaction to fire classification for floorings is:

Fire behaviour


Smoke production

A1fi to Fn(as applicable)

-

s

1 or 2 (as applicable)



i.e. A1nto Ffi (as applicable) -s1 or 2 (as applicable)

The format of the reaction to fire classification for linear pipe thermal insulation products is:

Fire behaviour


Smoke production


Flaming droplets

A1lto F L(as applicable)


s

1, 2 or 3 (as applicable)


d

0, 1 or 2 (as applicable)



i.e A1lto Fl(as applicable) - si, 2 or 3 (as applicable, dO, 1 or 2 (as applicable)

Reaction to fire classification: classification

4.3 Field of application

This classification is valid for the following product parameters (e.g. thickness, density...):

product property 1

Variation in product property 1

product property 2

Variation in product property 2

product property 3

Variation in product property 3

product property 4

Variation in product property 4

product property x etc.

Variation in product property x etc.



(include reference to the reference document + date used for undertaking this)

The classification is valid for the following end use applications:

Details of substrates and/or air gaps

Details of methods and means of fixing

Details of joints

Details of other aspects of end use conditions

5 Limitations

This classification document does not represent type approval or certification of the product.

Include the following statement when the product is being CE marked under attestation of conformity system 3:

“The classification assigned to the product in this report is appropriate to a declaration of conformity by the manufacturer within the context of system 3 attestation of conformity and CE marking under the Construction Products Directive.

The manufacturer has made a declaration, which is held on file. This confirms that the products design requires no specific processes, procedures or stages (e.g. no addition of flame-retardants, limitation of organic content, or addition of fillers) that are aimed at enhancing the fire performance in order to obtain the classification achieved. As a consequence the manufacturer has concluded that system 3 attestation is appropriate.

The test laboratory has, therefore, played no part in sampling the product for the test, although it holds appropriate references, supplied by the manufacturer, to provide for traceability of the samples tested.”

A

SIGNED

PPROVED

B

signature of person undertaking classification


signature of person authorising this report


ibliography
  1. EN 13238, Reaction to fire tests for building products — Conditioning procedures and general rules for selection of substrates

  2. EN ISO 13943, Fire safety — Vocabulary (ISO 13943:2000)

  3. E) CEN/TS 15447, Mounting and fixing in reaction to fire tests under the Construction

Products Directive О

  1. ISO 9705:1993, Fire tests — Full scale room test for surface products