C.4 Functional verification
Clause Numbers (CN) in this European Standard.
Table C.1 —Verification Results Table
CN |
Requirement |
Comments |
Results |
5.1 |
ATS configuration |
The set up according configuration in Figure 1. Including ARC under the verification. |
|
5.3 |
Applicable network standards |
Equipment EN 50136-2. |
|
6.2 |
Transmission link requirements |
|
|
6.2.2 |
Transmission links shared with other applications |
|
|
6.2.3 |
Transmission network equipment |
|
|
6.2.4 |
ATSN capacity |
|
|
6.2.5 |
Denial of service |
|
|
6.3 |
Performance |
|
|
6.3.2 |
Transmission time |
|
|
6.3.3 |
Monitoring of interconnections |
|
|
7 |
Verification of performance |
|
|
7.1 |
General |
|
|
7.2 |
ATSN performance |
|
|
7.3 |
Transmission time |
|
|
7.4 |
Verification interval |
|
|
7.5.1 |
Records |
|
|
7.5.2 |
Inspection of records |
|
|
7.5.3 |
Calculations |
|
|
8 |
Documentation |
|
|
Annex D
(normative)
Classes for category C
For the purpose of creating custom categorization for applications the following tables shall be used for reference.
Table D.1 —Transmission time classification
Class |
Transmission time s |
||||
DO |
D1 |
D2 |
D3 |
D4 |
|
Arithmetic mean of all transmissions |
- |
120 |
60 |
20 |
10 |
95 % of all transmissions |
240 |
240 |
80 |
30 |
15 |
Table D.2 — Transmission time, maximum values
Class |
Maximum time s |
||||
M0 |
M1 |
М2 |
М3 |
M4 |
|
Maximum acceptable transmission time |
- |
480 |
120 |
60 |
20 |
Table D.3 — Reporting time classification
Class |
Reporting time |
|||||||
T1 |
T1a |
T2 |
T3 |
T3a |
T4 |
T5 |
T6 |
|
Maximum period |
32 days |
49 h |
25 h |
5 h |
30 min |
180 s |
90s |
20 s |
Table D.4 — Availability classification
Class |
Availability |
|||||
A0 |
A1 |
A2 |
A3 |
A4 |
A4a |
|
ATSN availability yearly (%) |
No req. |
97% |
99% |
99,5 % |
99,8 % |
99,9% |
Monthly availability |
No req. |
75% |
91 % |
95% |
98,5 % |
99,3% |
Table D.5 — Substitution security
Class |
Substitution security |
||
SO |
S1 |
S2 |
|
Substitution security measures |
No measures |
Measures to detect substitution of the supervised premises transceiver by methods as described by the manufacturer or ATSP. |
Measures to detect substitution of the supervised premises transceiver as described in 6.8.1 |
Table D.6 — Information security
Class |
Information |
|||
IO |
11 |
I2 |
ІЗ |
|
Information security measures |
No measures |
Measures to prevent unauthorized reading of the information transmitted by methods as described by the manufacturer or ATSP. |
Measures to prevent unauthorized modification of the information transmitted by methods as described by the manufacturer or ATSP. |
Measures to prevent unauthorized reading and unauthorized modification of the information transmitted as described in 6.8.1 |
|
Bibliography |
EN 54-21 |
2006 Fire detection and fire alarm systems —Part 21: Alarm transmission and fault warning routing equipment |
EN 50131-1 |
2006 Alarm systems —Intrusion and hold-up systems —Part 1: System requirements |
EN 50134-1 |
Alarm systems — Social alarm systems —Part 1: System requirements |
CLC/TS 50136-7 |
2004 Alarm systems —Alarm transmission systems and equipment — Part 7: Application guidelines |
IEC 56/1197 |
Guidance on Communication Network Dependability Engineering |